Part Number Hot Search : 
TL431B OA180 EM685FP UGF3MB 00BGXI KBPC1502 KBPC1502 C32MX4XX
Product Description
Full Text Search
 

To Download TPS54340-15 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  tps54340 slvsbk0b ? october 2012 ? revised march 2014 tps54340 42 v input, 3.5 a, step down dc-dc converter with eco-mode ? 1 features 3 description the tps54340 is a 42 v, 3.5 a, step down regulator 1 ? 4.5 v to 42 v (45 v abs max) input range with an integrated high side mosfet. the device ? 3.5 a continuous current, 4.5 a minimum peak survives load dump pulses up to 45 v per iso 7637. inductor current limit current mode control provides simple external ? current mode control dc-dc converter compensation and flexible component selection. a low ripple pulse skip mode reduces the no load ? 92-m ? high-side mosfet supply current to 146 a. shutdown supply current is ? high efficiency at light loads with pulse skipping reduced to 1 a when the enable pin is pulled low. eco-mode ? undervoltage lockout is internally set at 4.3 v but can ? low dropout at light loads with integrated boot be increased using the enable pin. the output voltage recharge fet start up ramp is internally controlled to provide a ? 146 a operating quiescent current controlled start up and eliminate overshoot. ? 1 a shutdown current a wide switching frequency range allows either ? 100 khz to 2.5 mhz fixed switching frequency efficiency or external component size to be optimized. frequency foldback and thermal shutdown protects ? synchronizes to external clock internal and external components during an overload ? adjustable uvlo voltage and hysteresis condition. ? internal soft-start the tps54340 is available in an 8-terminal thermally ? accurate cycle-by-cycle current limit enhanced hsoic powerpad ? package. ? thermal, overvoltage, and frequency foldback protection device information ? 0.8 v 1% internal voltage reference order number package body size ? 8-terminal hsoic with powerpad ? package tps54340dda hsoic (8) 4,89mm x 3,9mm ? ? 40 c to 150 c t j operating range spacer ? supported by webench ? software tool spacer 2 applications 12 v, 24 v industrial, automotive and communications power systems 4 simplified schematic figure 1. efficiency vs load current 1 an important notice at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. production data. sw vin gnd boot fb comp tps54340 en rt/clk v in v out r1r3 0 10 20 30 40 50 60 70 80 100 0 0.5 1.0 1.5 2.0 i - output current - a o efficiency - % 2.5 3.0 90 3.5 v = 5v out v = 3.3v out v = 12v sw = 600 khz in f productfolder sample &buy technical documents tools & software support &community
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com table of contents 8.2 functional block diagram ....................................... 11 1 features .................................................................. 1 8.3 feature description ................................................. 11 2 applications ........................................................... 1 8.4 device functional modes ........................................ 22 3 description ............................................................. 1 9 application and implementation ........................ 24 4 simplified schematic ............................................. 1 9.1 application information ............................................ 24 5 revision history ..................................................... 2 9.2 typical application .................................................. 24 6 terminal configuration and functions ................ 3 10 power supply recommendations ..................... 34 7 specifications ......................................................... 4 11 layout ................................................................... 35 7.1 absolute maximum ratings ..................................... 4 11.1 layout guidelines ................................................. 35 7.2 handling ratings ....................................................... 4 11.2 layout example .................................................... 35 7.3 recommended operating conditions ....................... 4 12 device and documentation support ................. 36 7.4 thermal information .................................................. 4 12.1 trademarks ........................................................... 36 7.5 electrical characteristics ........................................... 5 12.2 electrostatic discharge caution ............................ 36 7.6 timing requirements ................................................ 6 12.3 glossary ................................................................ 36 7.7 typical characteristics .............................................. 6 13 mechanical, packaging, and orderable 8 detailed description ............................................ 10 information ........................................................... 36 8.1 overview ................................................................. 10 5 revision history note: page numbers for previous revisions may differ from page numbers in the current version. changes from revision a (february 2013) to revision b page ? changed the data sheet to the new ti layout ........................................................................................................................ 1 ? changed the application list from: 12 v, 24 v and 48 v industrial to: 12 v, 24 v industrial .............................................. 1 ? added the device information table ....................................................................................................................................... 1 ? added the handling ratings table .......................................................................................................................................... 4 ? added the recommended operating conditions table .......................................................................................................... 4 ? added the thermal information table inside the document ................................................................................................... 4 ? changed the operating: nonswitching supply current test conditions from: fb = 0.83 v to: fb = 0.9 v ................. 5 ? changed rt/clk high threshold max value from: 1.7 v to: 2 v ....................................................................................... 5 ? changed figure 7 title from: high frequency range to: low frequency range ............................................. 6 ? changed figure 8 title from: low frequency range to: high frequency range ............................................. 7 ? added the power supply recommendations section .......................................................................................................... 34 changes from original (october 2012) to revision a page ? changed figure 12 from: i en ( v) to: i en ( a) ..................................................................................................................... 7 ? changed figure 13 from: i en ( v) to: i en ( a) ..................................................................................................................... 7 2 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 6 terminal configuration and functions hsoic package (top view) terminal functions terminal i/o description name no. a bootstrap capacitor is required between boot and sw. if the voltage on this capacitor is below the boot 1 o minimum required to operate the high side mosfet, the output is switched off until the capacitor is refreshed. vin 2 i input supply voltage with 4.5 v to 42 v operating range. enable terminal, with internal pull-up current source. pull below 1.2 v to disable. float to enable. adjust the en 3 i input undervoltage lockout with two resistors. see the enable and adjusting undervoltage lockout section. resistor timing and external clock. an internal amplifier holds this terminal at a fixed voltage when using an external resistor to ground to set the switching frequency. if the terminal is pulled above the pll upper rt/clk 4 i threshold, a mode change occurs and the terminal becomes a synchronization input. the internal amplifier is disabled and the terminal is a high impedance clock input to the internal pll. if clocking edges stop, the internal amplifier is re-enabled and the operating mode returns to resistor frequency programming. fb 5 i inverting input of the transconductance (gm) error amplifier. error amplifier output and input to the output switch current (pwm) comparator. connect frequency comp 6 o compensation components to this terminal. gnd 7 ? ground sw 8 i the source of the internal high-side power mosfet and switching node of the converter. gnd terminal must be electrically connected to the exposed pad on the printed circuit board for proper thermal pad 9 ? operation. copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 3 product folder links: tps54340 gnd 7 comp 6 fb 5 sw 8 23 4 1 vin en rt/clk boot thermal pad 9
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com 7 specifications 7.1 absolute maximum ratings (1) over operating free-air temperature range (unless otherwise noted) min max unit vin ? 0.3 45 en ? 0.3 8.4 boot 53 input voltage v fb ? 0.3 3 comp ? 0.3 3 rt/clk ? 0.3 3.6 boot-sw 8 output voltage sw ? 0.6 45 v sw, 10-ns transient ? 2 45 operating junction temperature ? 40 150 c (1) stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. these are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. 7.2 handling ratings min max unit t stg storage temperature range ? 65 150 c human body model (hbm) esd stress voltage (2) 2 kv v esd (1) charged device model (hbm) esd stress voltage (3) 500 v (1) electrostatic discharge (esd) to measure device sensitivity and immunity to damage caused by assembly line electrostatic discharges into the device. (2) level listed above is the passing level per ansi/esda/jedec js-001. jedec document jep155 states that 500v hbm allows safe manufacturing with a standard esd control process. terminals listed as 1000v may actually have higher performance. (3) level listed above is the passing level per eia-jedec jesd22-c101. jedec document jep157 states that 250v cdm allows safe manufacturing with a standard esd control process. terminals listed as 250v may actually have higher performance. 7.3 recommended operating conditions over operating free-air temperature range (unless otherwise noted) min max unit v in supply input voltage 4.5 42 v v o output voltage 0.8 41.1 v i o output current 0 5 a t j junction temperature ? 40 150 c 7.4 thermal information tps54340 thermal metric (1) (2) unit dda (8 terminals) ja junction-to-ambient thermal resistance (standard board) 42.0 jt junction-to-top characterization parameter 5.9 jb junction-to-board characterization parameter 23.4 c/w jctop junction-to-case(top) thermal resistance 45.8 jcbot junction-to-case(bottom) thermal resistance 3.6 jb junction-to-board thermal resistance 23.4 (1) for more information about traditional and new thermal metrics, see the ic package thermal metrics application report, spra953 . (2) power rating at a specific ambient temperature t a should be determined with a junction temperature of 150 c. this is the point where distortion starts to substantially increase. see power dissipation estimate in application section of this data sheet for more information. 4 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 7.5 electrical characteristics t j = ? 40 c to 150 c, vin = 4.5 v to 42 v (unless otherwise noted) parameter test conditions min typ max unit supply voltage (vin terminal) operating input voltage 4.5 42 v internal undervoltage lockout threshold rising 4.1 4.3 4.48 v internal undervoltage lockout threshold 325 mv hysteresis shutdown supply current en = 0 v, 25 c, 4.5 v vin 42 v 1.3 3.5 a operating: nonswitching supply current fb = 0.9 v, t a = 25 c 146 175 enable and uvlo (en terminal) enable threshold voltage no voltage hysteresis, rising and falling 1.1 1.2 1.3 v enable threshold +50 mv ? 4.6 input current a enable threshold ? 50 mv ? 0.58 ? 1.2 -1.8 hysteresis current ? 2.2 ? 3.4 -4.5 a voltage reference voltage reference 0.792 0.8 0.808 v high-side mosfet on-resistance vin = 12 v, boot-sw = 6 v 92 190 m error amplifier input current 50 na error amplifier transconductance (g m ) ? 2 a < i comp < 2 a, v comp = 1 v 350 mhos error amplifier transconductance (g m ) during ? 2 a < i comp < 2 a, v comp = 1 v, v fb = 0.4 v 77 mhos soft-start error amplifier dc gain v fb = 0.8 v 10,000 v/v min unity gain bandwidth 2500 khz error amplifier source/sink v (comp) = 1 v, 100 mv overdrive 30 a comp to sw current transconductance 12 a/v current limit all v in and temperatures, open loop (1) 4.5 5.5 6.8 current limit threshold all temperatures, vin = 12 v, open loop (1) 4.5 5.5 6.25 a v in = 12 v, t a = 25 c, open loop (1) 5.2 5.5 5.85 thermal shutdown thermal shutdown 176 c thermal shutdown hysteresis 12 c timing resistor and external clock (rt/clk terminal) switching frequency range using rt mode 100 2500 khz f sw switching frequency r t = 200 k 450 500 550 khz switching frequency range using clk mode 160 2300 khz rt/clk high threshold 1.55 2 v rt/clk low threshold 0.5 1.2 v (1) open loop current limit measured directly at the sw terminal and is independent of the inductor value and slope compensation. copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 5 product folder links: tps54340
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com 7.6 timing requirements parameter test conditions min typ max unit enable and uvlo (en terminal) enable to comp active v in = 12 v , t a = 25 c 540 s internal soft-start time soft-start time f sw = 500 khz, 10% to 90% 2.1 ms soft-start time f sw = 2.5 mhz, 10% to 90% 0.42 ms high-side mosfet minimum controllable on time vin = 12 v, t a = 25 c 135 ns current limit current limit threshold delay 60 ns timing resistor and external clock (rt/clk terminal) minimum clk input pulse width 15 ns rt/clk falling edge to sw rising edge measured at 500 khz with rt resistor in series 55 ns delay pll lock in time measured at 500 khz 78 s 7.7 typical characteristics v in = 12v v in = 12 v figure 2. on resistance vs junction temperature figure 3. voltage reference vs junction temperature v in = 12v v in = 12 v figure 5. switch current limit vs input voltage figure 4. switch current limit vs junction temperature 6 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340 4.5 4.7 4.9 5.1 5.3 5.5 5.7 5.9 6.1 6.3 6.5 50 25 0 25 50 75 100 125 150 high side switch current (a) t j - junction temperature ( ? c) c027 4.5 4.7 4.9 5.1 5.3 5.5 5.7 5.9 6.1 6.3 6.5 0 5 15 20 25 30 40 35 45 v in ? input voltage (v) high-side switch current (a) t j = ?40c t j = 25c t j = 150c g004 10 0.784 0.789 0.794 0.799 0.804 0.809 0.814 50 25 0 25 50 75 100 125 150 v fb - voltage referance ( v) t j - junction temperature ( ? c) c026 0 0.05 0.1 0.15 0.2 0.25 ?50 ?25 0 25 50 75 100 125 150 t j ? junction temperature (c) r ds ( on ) ? on-state resistance ( w ) boot-sw = 3 vboot-sw = 6 v g001
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 typical characteristics (continued) v in = 12 v r t = 200 k ? sw (khz) = 92417 x r t (k ) -0.991 r t (k ) = 101756 x ? sw (khz) -1.008 figure 6. switching frequency vs junction temperature figure 7. switching frequency vs rt/clk resistance low frequency range v in = 12v v in = 12 v figure 8. switching frequency vs rt/clk resistance figure 9. ea transconductance vs junction temperature high frequency range v in = 12 v v in = 12 v figure 10. ea transconductance during soft-start vs figure 11. en terminal voltage vs junction temperature junction temperature copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 7 product folder links: tps54340 20 30 40 50 60 70 80 90 100 110 120 50 25 0 25 50 75 100 125 150 gm (a/v) t j - junction temperature ( ? c) c033 1.15 1.16 1.17 1.18 1.19 1.2 1.21 1.22 1.23 1.24 1.25 1.26 1.27 1.28 1.29 1.3 50 25 0 25 50 75 100 125 150 en - threshold (v) t j - junction temperature ( ? c) c034 200 250 300 350 400 450 500 50 25 0 25 50 75 100 125 150 gm (a/v) t j - junction temperature ( ? c) c032 0 500 1000 1500 2000 2500 0 50 100 150 200 rt/clk ? resistance (k w ) ? sw ? switching frequency (khz) g007 450 460 470 480 490 500 510 520 530 540 550 50 25 0 25 50 75 100 125 150 f s - switching frequency (khz) t j - junction temperature ( ? c) c029 0 50 100 150 200 250 300 350 400 450 500 200 300 400 500 600 700 800 900 1000 f sw - switching frequency (khz) rt/clk - resistance (k ) c030
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com typical characteristics (continued) v in = 12 v i en = threshold +50 mv v in = 5 v i en = threshold +50 mv figure 13. en terminal current vs junction temperature figure 12. en terminal current vs junction temperature v in = 12v v in = 12 v figure 15. switching frequency vs fb figure 14. en terminal current hysteresis vs junction temperature v in = 12 v t j = 25 c figure 16. shutdown supply current vs junction figure 17. shutdown supply current vs input voltage (v in ) temperature 8 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340 0 0.5 1 1.5 2 2.5 3 50 25 0 25 50 75 100 125 150 i vin (a) t j - junction temperature ( ? c) c039 0 0.5 1 1.5 2 2.5 3 0 10 20 30 40 50 60 i vin (a) v in - input voltage (v) c040 4.5 4.3 4.1 3.9 3.7 3.5 3.3 3.1 2.9 2.7 2.5 50 25 0 25 50 75 100 125 150 i en - hysteresis (a) t j - junction temperature ( ? c) c037 0 25 50 75 100 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 v fb (v) % of nominal switching frequency v fb falling v fb rising g013 2.5 2.3 2.1 1.9 1.7 1.5 1.3 1.1 0.9 0.7 0.5 50 25 0 25 50 75 100 125 150 i en (a) t j - junction temperature ( ? c) c036 ?5 ?4.9 ?4.8 ?4.7 ?4.6 ?4.5 ?4.4 ?4.3 ?4.2 ?4.1 ?4 ?50 ?25 0 25 50 75 100 125 150 tj ? junction temperature (c) i en (a) g012
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 typical characteristics (continued) t j = 25 c v in = 12 v figure 19. v in supply current vs input voltage figure 18. v in supply current vs junction temperature figure 20. boot-sw uvlo vs junction temperature figure 21. input voltage uvlo vs junction temperature v in = 12 v t j = 25 c figure 22. soft-start time vs switching frequency copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 9 product folder links: tps54340 0 1 2 3 4 5 6 7 8 9 10 100 300 500 700 900 1100 1300 1500 1700 1900 2100 2300 2500 soft-start time (ms) switching frequency (khz) c045 1.8 1.9 2 2.1 2.2 2.3 2.4 2.5 2.6 ?50 ?25 0 25 50 75 100 125 150 t j ? junction temperature (c) v in ? (boot?sw) (db) boot-sw uvlo fallingboot-sw uvlo rising g018 3.7 3.8 3.9 4 4.1 4.2 4.3 4.4 4.5 ?50 ?25 0 25 50 75 100 125 150 tj ? junction temperature (c) input voltage (v) uvlo start switchinguvlo stop switching g019 70 90 110 130 150 170 190 210 50 25 0 25 50 75 100 125 150 i vin (a) t j - junction temperature ( ? c) c041 70 90 110 130 150 170 190 210 0 v in ? input voltage (v) v in ? supply current (a) g018 5 15 20 25 30 40 35 45 10
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com 8 detailed description 8.1 overview the tps54340 is a 42 v, 3.5 a, step-down (buck) regulator with an integrated high side n-channel mosfet. the device implements constant frequency, current mode control which reduces output capacitance and simplifies external frequency compensation. the wide switching frequency range of 100 khz to 2500 khz allows either efficiency or size optimization when selecting the output filter components. the switching frequency is adjusted using a resistor to ground connected to the rt/clk terminal. the device has an internal phase-locked loop (pll) connected to the rt/clk terminal that will synchronize the power switch turn on to a falling edge of an external clock signal. the tps54340 has a default input start-up voltage of approximately 4.3 v. the en terminal can be used to adjust the input voltage undervoltage lockout (uvlo) threshold with two external resistors. an internal pull up current source enables operation when the en terminal is floating. the operating current is 146 a under no load condition (not switching). when the device is disabled, the supply current is 1 a. the integrated 92m high side mosfet supports high efficiency power supply designs capable of delivering 3.5 amperes of continuous current to a load. the gate drive bias voltage for the integrated high side mosfet is supplied by a bootstrap capacitor connected from the boot to sw terminals. the tps54340 reduces the external component count by integrating the bootstrap recharge diode. the boot terminal capacitor voltage is monitored by a uvlo circuit which turns off the high side mosfet when the boot to sw voltage falls below a preset threshold. an automatic boot capacitor recharge circuit allows the tps54340 to operate at high duty cycles approaching 100%. therefore, the maximum output voltage is near the minimum input supply voltage of the application. the minimum output voltage is the internal 0.8 v feedback reference. output overvoltage transients are minimized by an overvoltage transient protection (ovp) comparator. when the ovp comparator is activated, the high side mosfet is turned off and remains off until the output voltage is less than 106% of the desired output voltage. the tps54340 includes an internal soft-start circuit that slows the output rise time during start-up to reduce in- rush current and output voltage overshoot. output overload conditions reset the soft-start timer. when the overload condition is removed, the soft-start circuit controls the recovery from the fault output level to the nominal regulation voltage. a frequency foldback circuit reduces the switching frequency during start-up and overcurrent fault conditions to help maintain control of the inductor current. 10 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 8.2 functional block diagram 8.3 feature description 8.3.1 fixed frequency pwm control the tps54340 uses fixed frequency, peak current mode control with adjustable switching frequency. the output voltage is compared through external resistors connected to the fb terminal to an internal voltage reference by an error amplifier. an internal oscillator initiates the turn on of the high side power switch. the error amplifier output at the comp terminal controls the high side power switch current. when the high side mosfet switch current reaches the threshold level set by the comp voltage, the power switch is turned off. the comp terminal voltage will increase and decrease as the output current increases and decreases. the device implements current limiting by clamping the comp terminal voltage to a maximum level. the pulse skipping eco-mode is implemented with a minimum voltage clamp on the comp terminal. 8.3.2 slope compensation output current the tps54340 adds a compensating ramp to the mosfet switch current sense signal. this slope compensation prevents sub-harmonic oscillations at duty cycles greater than 50%. the peak current limit of the high side switch is not affected by the slope compensation and remains constant over the full duty cycle range. copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 11 product folder links: tps54340 error amplifier boot charge boot uvlo uvlo current sense oscillator with pll frequency foldback logic slope compensation pwm comparator minimum clamp pulse skip maximum clamp voltage reference reference dac for soft - start fb comp rt/ clk sw boot vin gnd thermal shutdown en enable comparator shutdown logic shutdown enable threshold 6 8/8/ 2012 a 0192789 powerpad shutdown ov
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com feature description (continued) 8.3.3 pulse skip eco-mode the tps54340 operates in a pulse skipping eco-mode at light load currents to improve efficiency by reducing switching and gate drive losses. if the output voltage is within regulation and the peak switch current at the end of any switching cycle is below the pulse skipping current threshold, the device enters eco-mode. the pulse skipping current threshold is the peak switch current level corresponding to a nominal comp voltage of 600 mv. when in eco-mode, the comp terminal voltage is clamped at 600 mv and the high side mosfet is inhibited. since the device is not switching, the output voltage begins to decay. the voltage control loop responds to the falling output voltage by increasing the comp terminal voltage. the high side mosfet is enabled and switching resumes when the error amplifier lifts comp above the pulse skipping threshold. the output voltage recovers to the regulated value, and comp eventually falls below the eco-mode pulse skipping threshold at which time the device again enters eco-mode. the internal pll remains operational when in eco-mode. when operating at light load currents in eco-mode, the switching transitions occur synchronously with the external clock signal. during eco-mode operation, the tps54340 senses and controls peak switch current, not the average load current. therefore the load current at which the device enters eco-mode is dependent on the output inductor value. the circuit in figure 36 enters eco-mode at about 31.4 ma output current. as the load current approaches zero, the device enters a pulse skip mode during which it draws only 146 a input quiescent current. 8.3.4 low dropout operation and bootstrap voltage (boot) the tps54340 provides an integrated bootstrap voltage regulator. a small capacitor between the boot and sw terminals provides the gate drive voltage for the high side mosfet. the boot capacitor is refreshed when the high side mosfet is off and the external low side diode conducts. the recommended value of the boot capacitor is 0.1 f. a ceramic capacitor with an x7r or x5r grade dielectric with a voltage rating of 10 v or higher is recommended for stable performance over temperature and voltage. when operating with a low voltage difference from input to output, the high side mosfet of the tps54340 will operate at 100% duty cycle as long as the boot to sw terminal voltage is greater than 2.1v. when the voltage from boot to sw drops below 2.1v, the high side mosfet is turned off and an integrated low side mosfet pulls sw low to recharge the boot capacitor. to reduce the losses of the small low side mosfet at high output voltages, it is disabled at 24 v output and re-enabled when the output reaches 21.5 v. since the gate drive current sourced from the boot capacitor is small, the high side mosfet can remain on for many switching cycles before the mosfet is turned off to refresh the capacitor. thus the effective duty cycle of the switching regulator can be high, approaching 100%. the effective duty cycle of the converter during dropout is mainly influenced by the voltage drops across the power mosfet, the inductor resistance, the low side diode voltage and the printed circuit board resistance. the start and stop voltage for a typical 5 v output application is shown in figure 23 where the vin voltage is plotted versus load current. the start voltage is defined as the input voltage needed to regulate the output within 1% of nominal. the stop voltage is defined as the input voltage at which the output drops by 5% or where switching stops. during high duty cycle (low dropout) conditions, inductor current ripple increases when the boot capacitor is being recharged resulting in an increase in output voltage ripple. increased ripple occurs when the off time required to recharge the boot capacitor is longer than the high side off time associated with cycle by cycle pwm control. spacer 12 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 feature description (continued) figure 23. 5v start/stop voltage 8.3.5 error amplifier the tps54340 voltage regulation loop is controlled by a transconductance error amplifier. the error amplifier compares the fb terminal voltage to the lower of the internal soft-start voltage or the internal 0.8 v voltage reference. the transconductance (gm) of the error amplifier is 350 a/v during normal operation. during soft- start operation, the transconductance is reduced to 78 a/v and the error amplifier is referenced to the internal soft-start voltage. the frequency compensation components (capacitor, series resistor and capacitor) are connected between the error amplifier output comp terminal and gnd terminal. 8.3.6 adjusting the output voltage the internal voltage reference produces a precise 0.8 v 1% voltage reference over the operating temperature and voltage range by scaling the output of a bandgap reference circuit. the output voltage is set by a resistor divider from the output node to the fb terminal. it is recommended to use 1% tolerance or better divider resistors. select the low side resistor r ls for the desired divider current and use equation 1 to calculate r hs . to improve efficiency at light loads consider using larger value resistors. however, if the values are too high, the regulator will be more susceptible to noise and voltage errors from the fb input current may become noticeable. (1) 8.3.7 enable and adjusting undervoltage lockout the tps54340 is enabled when the vin terminal voltage rises above 4.3 v and the en terminal voltage exceeds the enable threshold of 1.2 v. the tps54340 is disabled when the vin terminal voltage falls below 4 v or when the en terminal voltage is below 1.2 v. the en terminal has an internal pull-up current source, i1, of 1.2 a that enables operation of the tps54340 when the en terminal floats. if an application requires a higher undervoltage lockout (uvlo) threshold, use the circuit shown in figure 24 to adjust the input voltage uvlo with two external resistors. when the en terminal voltage exceeds 1.2 v, an additional 3.4 a of hysteresis current, ihys, is sourced out of the en terminal. when the en terminal is pulled below 1.2 v, the 3.4 a ihys current is removed. this addional current facilitates adjustable input voltage uvlo hysteresis. use equation 2 to calculate r uvlo1 for the desired uvlo hysteresis voltage. use equation 3 to calculate r uvlo2 for the desired vin start voltage. in applications designed to start at relatively low input voltages (e.g., 4.5 v) and withstand high input voltages (e.g., 40 v), the en terminal may experience a voltage greater than the absolute maximum voltage of 8.4 v during the high input voltage condition. it is recommended to use a zener diode to clamp the terminal voltage below the absolute maximum rating. copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 13 product folder links: tps54340 hs ls vout 0.8v r = r 0.8 v - ? ? ? ? 4.7 0 0.1 0.15 0.35 0.5 load current - a v - input voltage - v i start stop 4.8 4.9 5 5.1 5.34.6 5.4 5.5 5.65.2 0.05 0.25 0.2 0.3 0.4 0.45 dropout voltage dropout voltage
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com feature description (continued) figure 24. adjustable undervoltage lockout (uvlo) (2) (3) 8.3.8 internal soft-start the tps54340 has an internal digital soft-start that ramps the reference voltage from zero volts to its final value in 1024 switching cycles. the internal soft-start time (10% to 90%) is calculated using equation 4 . (4) if the en terminal is pulled below the stop threshold of 1.2 v, switching stops and the internal soft-start resets. the soft-start also resets in thermal shutdown. 8.3.9 constant switching frequency and timing resistor (rt/clk) terminal) the switching frequency of the tps54340 is adjustable over a wide range from 100 khz to 2500 khz by placing a resistor between the rt/clk terminal and gnd terminal. the rt/clk terminal voltage is typically 0.5 v and must have a resistor to ground to set the switching frequency. to determine the timing resistance for a given switching frequency, use equation 5 or equation 6 or the curves in figure 6 and figure 7 . to reduce the solution size one would typically set the switching frequency as high as possible, but tradeoffs of the conversion efficiency, maximum input voltage and minimum controllable on time should be considered. the minimum controllable on time is typically 135 ns which limits the maximum operating frequency in applications with high input to output step down ratios. the maximum switching frequency is also limited by the frequency foldback circuit. a more detailed discussion of the maximum switching frequency is provided in the next section. (5) (6) 14 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340 1.008 101756 sw (khz) = rt (k ) f w 0.991 92417 rt (k ) = sw (khz) f w f = ss sw 1024 t (ms) (khz) = - + ena uvlo2 start ena 1 uvlo1 v r v v i r - = start stop uvlo1 hys v v r i tps54340 i vin r uvlo1 r uvlo2 en optional v en ihys 1
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 feature description (continued) 8.3.10 accurate current limit operation and maximum switching frequency the tps54340 implements peak current mode control in which the comp terminal voltage controls the peak current of the high side mosfet. a signal proportional to the high side switch current and the comp terminal voltage are compared each cycle. when the peak switch current intersects the comp control voltage, the high side switch is turned off. during overcurrent conditions that pull the output voltage low, the error amplifier increases switch current by driving the comp terminal high. the error amplifier output is clamped internally at a level which sets the peak switch current limit. the tps54340 provides an accurate current limit threshold with a typical current limit delay of 60 ns. with smaller inductor values, the delay will result in a higher peak inductor current. the relationship between the inductor value and the peak inductor current is shown in figure 25 . figure 25. current limit delay to protect the converter in overload conditions at higher switching frequencies and input voltages, the tps54340 implements a frequency foldback. the oscillator frequency is divided by 1, 2, 4, and 8 as the fb terminal voltage falls from 0.8 v to 0 v. the tps54340 uses a digital frequency foldback to enable synchronization to an external clock during normal start-up and fault conditions. during short-circuit events, the inductor current can exceed the peak current limit because of the high input voltage and the minimum controllable on time. when the output voltage is forced low by the shorted load, the inductor current decreases slowly during the switch off time. the frequency foldback effectively increases the off time by increasing the period of the switching cycle providing more time for the inductor current to ramp down. with a maximum frequency foldback ratio of 8, there is a maximum frequency at which the inductor current can be controlled by frequency foldback protection. equation 8 calculates the maximum switching frequency at which the inductor current will remain under control when v out is forced to v out(sc) . the selected operating frequency should not exceed the calculated value. equation 7 calculates the maximum switching frequency limitation set by the minimum controllable on time and the input to output step down ratio. setting the switching frequency above this value will cause the regulator to skip switching pulses to achieve the low duty cycle required at maximum input voltage. (7) copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 15 product folder links: tps54340 ( ) ( ) o dc out d sw max skip on in o d ds on i r v v 1 t v i r v f ? ? + + ? = ? - + ? t on t cldelay inductor current (a) clpeak peak inductor current open loop current limit clpeak = v /l x t in cldelay
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com feature description (continued) (8) i o output current i cl current limit rdc inductor resistance v in maximum input voltage v out output voltage v outsc output voltage during short vd diode voltage drop r ds(on) switch on resistance t on controllable on time ? div frequency divide equals (1, 2, 4, or 8) 8.3.11 synchronization to rt/clkterminal the rt/clk terminal can receive a frequency synchronization signal from an external system clock. to implement this synchronization feature connect a square wave to the rt/clk terminal through either circuit network shown in figure 26 . the square wave applied to the rt/clk terminal must switch lower than 0.5 v and higher than 1.7 v and have a pulsewidth greater than 15 ns. the synchronization frequency range is 160 khz to 2300 khz. the rising edge of the sw will be synchronized to the falling edge of rt/clk terminal signal. the external synchronization circuit should be designed such that the default frequency set resistor is connected from the rt/clk terminal to ground when the synchronization signal is off. when using a low impedance signal source, the frequency set resistor is connected in parallel with an ac coupling capacitor to a termination resistor (e.g., 50 ) as shown in figure 26 . the two resistors in series provide the default frequency setting resistance when the signal source is turned off. the sum of the resistance should set the switching frequency close to the external clk frequency. it is recommended to ac couple the synchronization signal through a 10 pf ceramic capacitor to rt/clk terminal. the first time the rt/clk is pulled above the pll threshold the tps54340 switches from the rt resistor free- running frequency mode to the pll synchronized mode. the internal 0.5 v voltage source is removed and the rt/clk terminal becomes high impedance as the pll starts to lock onto the external signal. the switching frequency can be higher or lower than the frequency set with the rt/clk resistor. the device transitions from the resistor mode to the pll mode and locks onto the external clock frequency within 78 microseconds. during the transition from the pll mode to the resistor programmed mode, the switching frequency will fall to 150 khz and then increase or decrease to the resistor programmed frequency when the 0.5 v bias voltage is reapplied to the rt/clk resistor. the switching frequency is divided by 8, 4, 2, and 1 as the fb terminal voltage ramps from 0 to 0.8 volts. the device implements a digital frequency foldback to enable synchronizing to an external clock during normal start- up and fault conditions. figure 27 , figure 28 and figure 29 show the device synchronized to an external system clock in continuous conduction mode (ccm), discontinuous conduction (dcm), and pulse skip mode (eco-mode). figure 26. synchronizing to a system clock 16 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340 rt/clk tps54340 clock source pll rt rt/clk tps54340 hi-z clock source pll rt ( ) ( ) f f ? ? + + ? = ? - + ? cl dc d out sc div sw(shift) on in cl d ds on i r v v t v i r v
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 feature description (continued) figure 27. plot of synchronizing in ccm figure 28. plot of synchronizing in dcm figure 29. plot of synchronizing in eco-mode 8.3.12 overvoltage protection the tps54340 incorporates an output overvoltage protection (ovp) circuit to minimize voltage overshoot when recovering from output fault conditions or strong unload transients in designs with low output capacitance. for example, when the power supply output is overloaded the error amplifier compares the actual output voltage to the internal reference voltage. if the fb terminal voltage is lower than the internal reference voltage for a considerable time, the output of the error amplifier will increase to a maximum voltage corresponding to the peak current limit threshold. when the overload condition is removed, the regulator output rises and the error amplifier output transitions to the normal operating level. in some applications, the power supply output voltage can increase faster than the response of the error amplifier output resulting in an output overshoot. copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 17 product folder links: tps54340 ext il sw ext il sw il ext sw
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com feature description (continued) the ovp feature minimizes output overshoot when using a low value output capacitor by comparing the fb terminal voltage to the rising ovp threshold which is nominally 109% of the internal voltage reference. if the fb terminal voltage is greater than the rising ovp threshold, the high side mosfet is immediately disabled to minimize output overshoot. when the fb voltage drops below the falling ovp threshold which is nominally 106% of the internal voltage reference, the high side mosfet resumes normal operation. 8.3.13 thermal shutdown the tps54340 provides an internal thermal shutdown to protect the device when the junction temperature exceeds 176 c. the high side mosfet stops switching when the junction temperature exceeds the thermal trip threshold. once the die temperature falls below 164 c, the device reinitiates the power up sequence controlled by the internal soft-start circuitry. 8.3.14 small signal model for loop response figure 30 shows an equivalent model for the tps54340 control loop which can be simulated to check the frequency response and dynamic load response. the error amplifier is a transconductance amplifier with a gm ea of 3350 a/v. the error amplifier can be modeled using an ideal voltage controlled current source. the resistor r o and capacitor c o model the open loop gain and frequency response of the amplifier. the 1mv ac voltage source between the nodes a and b effectively breaks the control loop for the frequency response measurements. plotting c/a provides the small signal response of the frequency compensation. plotting a/b provides the small signal response of the overall loop. the dynamic loop response can be evaluated by replacing r l with a current source with the appropriate load step amplitude and step rate in a time domain analysis. this equivalent model is only valid for continuous conduction mode (ccm) operation. figure 30. small signal model for loop response 8.3.15 simple small signal model for peak current mode control figure 31 describes a simple small signal model that can be used to design the frequency compensation. the tps54340 power stage can be approximated by a voltage-controlled current source (duty cycle modulator) supplying current to the output capacitor and load resistor. the control to output transfer function is shown in equation 9 and consists of a dc gain, one dominant pole, and one esr zero. the quotient of the change in switch current and the change in comp terminal voltage (node c in figure 30 ) is the power stage transconductance, gm ps . the gm ps for the tps54340 is 12 a/v. the low-frequency gain of the power stage is the product of the transconductance and the load resistance as shown in equation 10 . 18 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340 fb comp v o r1 r3 c1 c2 r2 co ro gm ea 350 m a/v 0.8 v power stage gm 12 a/v ps sw r esr c out r l b a c
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 feature description (continued) as the load current increases and decreases, the low-frequency gain decreases and increases, respectively. this variation with the load may seem problematic at first glance, but fortunately the dominant pole moves with the load current (see equation 11 ). the combined effect is highlighted by the dashed line in the right half of figure 31 . as the load current decreases, the gain increases and the pole frequency lowers, keeping the 0-db crossover frequency the same with varying load conditions. the type of output capacitor chosen determines whether the esr zero has a profound effect on the frequency compensation design. using high esr aluminum electrolytic capacitors may reduce the number frequency compensation components needed to stabilize the overall loop because the phase margin is increased by the esr zero of the output capacitor (see equation 12 ). figure 31. simple small signal model and frequency response for peak current mode control (9) (10) (11) (12) 8.3.16 small signal model for frequency compensation the tps54340 uses a transconductance amplifier for the error amplifier and supports three of the commonly- used frequency compensation circuits. compensation circuits type 2a, type 2b, and type 1 are shown in figure 32 . type 2 circuits are typically implemented in high bandwidth power-supply designs using low esr output capacitors. the type 1 circuit is used with power-supply designs with high-esr aluminum electrolytic or tantalum capacitors. equation 13 and equation 14 relate the frequency response of the amplifier to the small signal model in figure 32 . the open-loop gain and bandwidth are modeled using the r o and c o shown in figure 32 . see the application section for a design example using a type 2a network with a low esr output capacitor. equation 13 through equation 22 are provided as a reference. an alternative is to use webench software tools to create a design based on the power supply requirements. copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 19 product folder links: tps54340 z out esr 1 c r 2 = p f p out l 1 f c r 2 = p ps l adc = gm r z out c p s 1 2 v adc v s 1 2 ? ? + ? p ? = ? ? + ? p ? f f v o r esr c out r l vc gm ps fp fz adc
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com feature description (continued) figure 32. types of frequency compensation figure 33. frequency response of the type 2a and type 2b frequency compensation (13) (14) (15) (16) (17) (18) 20 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340 1 p1 2 ro c1 = p ea r2 a1 = gm ro| | r3 r1 + r2 ea r2 a0 = gm ro r1 + r2 f f f z1 p1 p2 s 1 2 ea a0 s s 1 1 2 2 ? ? + ? p ? = ? ? ? ? + + ? ? p p ? ? p ea o gm c = 2 bw (hz) ea aol(v/v) ro = gm a0a1 p1 z1 p2 aol bw vref v o r1 r3 c1 c2 r2 c o r o gm ea comp fb type 2a type 2b type 1 c2 r3 c1
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 feature description (continued) (19) (20) (21) (22) copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 21 product folder links: tps54340 p o o 1 p2 = type 1 2 r (c2 + c ) p o o 1 p2 = type 2b 2 r3 | | r c p o o 1 p2 = type 2a 2 r3 | | r (c2 + c ) 1 z1 2 r3 c1 = p
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com 8.4 device functional modes 8.4.1 operation with v in < 4.5 v (minimum v in ) the device is recommended to operate with input voltages above 4.5 v. the typical vin uvlo threshold is 4.3 v and the device may operate at input voltages down to the uvlo voltage. at input voltages below the actual uvlo voltage, the device will not switch. if en is externally pulled up to v in or left floating, when v in passes the uvlo threshold the device will become active. switching is enabled the soft start sequence is initiated. the tps54340 will start at the soft start time determined by the internal soft start time. 8.4.2 operation with en control the enable threshold voltage is 1.2 v typical. with en held below that voltage the device is disabled and switching is inhibited even if v in is above its uvlo threshold. the ic quiescent current is reduced in this state. if the en voltage is increased above the threshold while v in is above its uvlo threshold, the device becomes active. switching is enabled, and the soft start sequence is initiated. the tps54340 will start at the soft start time determined by the internal soft start time. 8.4.3 alternate power supply topologies 8.4.3.1 inverting power the tps54340 can be used to convert a positive input voltage to a split rail positive and negative output voltage by using a coupled inductor. idea applications are amplifiers requiring a split rail positive and negative voltage power supply. for a more detailed example see slva369 . figure 34. tps54340 split rail power supply 22 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340 sw vin gnd boot fb comp tps54340 en rt/clk cpole czero rcomp rt coneg lo cboot cin r1 r2 cd vin voneg + + gnd vopos copos +
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 device functional modes (continued) 8.4.3.2 split rail power supply the tps54340 can be used to convert a positive input voltage to a negative output voltage. idea applications are amplifiers requiring a negative power supply. for a more detailed example see slva317 . figure 35. tps54340 inverting power supply from slva317 application note copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 23 product folder links: tps54340 sw vin gnd boot fb comp tps54340 en rt/clk cpole czero rcomp rt co lo cboot cin r1 r2 cd vin vout + + gnd
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com 9 application and implementation 9.1 application information the tps54340 is a 42 v, 3.5 a, step down regulator with an integrated high side mosfet. idea applications are: 12 v, 24 v industrial, automotive and communications power systems. 9.2 typical application figure 36. 3.3 v output tps54340 design example 9.2.1 design requirements this guide illustrates the design of a high frequency switching regulator using ceramic output capacitors. a few parameters must be known in order to start the design process. these requirements are typically determined at the system level. for this example, we will start with the following known parameters: table 1. design parameters design parameters example values output voltage 3.3 v transient response 0.875 a to 2.625 a load step v out = 4 % maximum output current 3.5 a input voltage 12 v nom. 6 v to 42 v output voltage ripple 0.5% of v out start input voltage (rising vin) 5.75 v stop input voltage (falling vin) 4.5 v 9.2.2 detailed design procedures 9.2.2.1 selecting the switching frequency the first step is to choose a switching frequency for the regulator. typically, the designer uses the highest switching frequency possible since this produces the smallest solution size. high switching frequency allows for lower value inductors and smaller output capacitors compared to a power supply that switches at a lower frequency. the switching frequency that can be selected is limited by the minimum on-time of the internal power switch, the input voltage, the output voltage and the frequency foldback protection. 24 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340 6v to 42v 3.3v, 3.5a 1 boot 2 vin 3 en 4 rt/clk 5 fb 6 comp 7 gnd 8 sw 9 pwrpd u1 tps54340dda c5 5600pf r4 11.5k c8 47pf c4 0.1uf l1 5.6uh r6 10.2k r5 31.6k r3 162k r1 365k r2 86.6k c1 2.2uf c2 2.2uf d1 b560c c6 100uf gnd fb gnd gnd gnd vin fb vout gnd
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 equation 7 and equation 8 should be used to calculate the upper limit of the switching frequency for the regulator. choose the lower value result from the two equations. switching frequencies higher than these values results in pulse skipping or the lack of overcurrent protection during a short circuit. the typical minimum on time, t onmin , is 135 ns for the tps54340. for this example, the output voltage is 3.3 v and the maximum input voltage is 42 v, which allows for a maximum switch frequency up to 712 khz to avoid pulse skipping from equation 7 . to ensure overcurrent runaway is not a concern during short circuits use equation 8 to determine the maximum switching frequency for frequency foldback protection. with a maximum input voltage of 42 v, assuming a diode voltage of 0.7 v, inductor resistance of 21 m , switch resistance of 92 m , a current limit value of 4.7 a and short circuit output voltage of 0.1 v, the maximum switching frequency is 1260 khz. for this design, a lower switching frequency of 600 khz is chosen to operate comfortably below the calculated maximums. to determine the timing resistance for a given switching frequency, use equation 5 or the curve in figure 7 . the switching frequency is set by resistor r 3 shown in figure 36 . for 600 khz operation, the closest standard value resistor is 162 k . (23) (24) (25) 9.2.2.2 output inductor selection (l o ) to calculate the minimum value of the output inductor, use equation 26 . k ind is a ratio that represents the amount of inductor ripple current relative to the maximum output current. the inductor ripple current is filtered by the output capacitor. therefore, choosing high inductor ripple currents impacts the selection of the output capacitor since the output capacitor must have a ripple current rating equal to or greater than the inductor ripple current. in general, the inductor ripple value is at the discretion of the designer, however, the following guidelines may be used. for designs using low esr output capacitors such as ceramics, a value as high as k ind = 0.3 may be desirable. when using higher esr output capacitors, k ind = 0.2 yields better results. since the inductor ripple current is part of the current mode pwm control system, the inductor ripple current should always be greater than 150 ma for stable pwm operation. in a wide input voltage regulator, it is best to choose relatively large inductor ripple current. this provides sufficienct ripple current with the input voltage at the minimum. for this design example, k ind = 0.3 and the minimum inductor value is calculated to be 4.8 h. the nearest standard value is 5.6 h. it is important that the rms current and saturation current ratings of the inductor not be exceeded. the rms and peak inductor current can be found from equation 28 and equation 29 . for this design, the rms inductor current is 3.5 a and the peak inductor current is 3.95 a. the chosen inductor is a we 7443552560, which has a saturation current rating of 7.5 a and an rms current rating of 6.7 a. as the equation set demonstrates, lower ripple currents will reduce the output voltage ripple of the regulator but will require a larger value of inductance. selecting higher ripple currents will increase the output voltage ripple of the regulator but allow for a lower inductance value. the current flowing through the inductor is the inductor ripple current plus the output current. during power up, faults or transient load conditions, the inductor current can increase above the peak inductor current level calculated above. in transient conditions, the inductor current can increase up to the switch current limit of the device. for this reason, the most conservative design approach is to choose an inductor with a saturation current rating equal to or greater than the switch current limit of the tps54340 which is nominally 5.5 a. copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 25 product folder links: tps54340 w w 0.991 92417 rt (k ) = = 163 k 600 (khz) f w + + ? ? = = ? w + ? sw(shift) 8 4.7 a x 21 m 0.1 v 0.7 v 1260 khz 135 ns 42 v - 4.7 a x 92 m 0.7 v f w + + ? ? = = ? w + ? sw(max skip) 1 3.5 a x 21 m 3.3 v 0.7 v 712 khz 135ns 42 v - 3.5 a x 92 m 0.7 v
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com (26) spacer (27) spacer (28) spacer (29) 9.2.2.3 output capacitor there are three primary considerations for selecting the value of the output capacitor. the output capacitor determines the modulator pole, the output voltage ripple, and how the regulator responds to a large change in load current. the output capacitance needs to be selected based on the most stringent of these three criteria. the desired response to a large change in the load current is the first criteria. the output capacitor needs to supply the increased load current until the regulator responds to the load step. the regulator does not respond immediately to a large, fast increase in the load current such as transitioning from no load to a full load. the regulator usually needs two or more clock cycles for the control loop to sense the change in output voltage and adjust the peak switch current in response to the higher load. the output capacitance must be large enough to supply the difference in current for 2 clock cycles to maintain the output voltage within the specified range. equation 30 shows the minimum output capacitance necessary, where i out is the change in output current, ? sw is the regulators switching frequency and v out is the allowable change in the output voltage. for this example, the transient load response is specified as a 4% change in v out for a load step from 0.875 a to 2.625 a. therefore, i out is 2.625 a - 0.875 a = 1.75 a and v out = 0.04 3.3 = 0.13 v. using these numbers gives a minimum capacitance of 44.9 f. this value does not take the esr of the output capacitor into account in the output voltage change. for ceramic capacitors, the esr is usually small enough to be ignored. aluminum electrolytic and tantalum capacitors have higher esr that must be included in load step calculations. the output capacitor must also be sized to absorb energy stored in the inductor when transitioning from a high to low load current. the catch diode of the regulator can not sink current so energy stored in the inductor can produce an output voltage overshoot when the load current rapidly decreases. a typical load step response is shown in . the excess energy absorbed in the output capacitor will increase the voltage on the capacitor. the capacitor must be sized to maintain the desired output voltage during these transient periods. equation 31 calculates the minimum capacitance required to keep the output voltage overshoot to a desired value, where l o is the value of the inductor, i oh is the output current under heavy load, i ol is the output under light load, v f is the peak output voltage, and v i is the initial voltage. for this example, the worst case load step will be from 2.625 a to 0.875 a. the output voltage increases during this load transition and the stated maximum in our specification is 4 % of the output voltage. this makes v f = 1.04 3.3 = 3.432. vi is the initial capacitor voltage which is the nominal output voltage of 3.3 v. using these numbers in equation 31 yields a minimum capacitance of 38.6 f. equation 32 calculates the minimum output capacitance needed to meet the output voltage ripple specification, where ? sw is the switching frequency, v oripple is the maximum allowable output voltage ripple, and i ripple is the inductor ripple current. equation 32 yields 11.4 f. equation 33 calculates the maximum esr an output capacitor can have to meet the output voltage ripple specification. equation 33 indicates the esr should be less than 18 m . the most stringent criteria for the output capacitor is 44.9 f required to maintain the output voltage within regulation tolerance during a load transient. 26 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340 ( ) = + = + = ripple out l peak i 0.905 a i i 3.5 a 3.95 a 2 2 ( ) ( ) ( ) ( ) ( ) ( ) ( ) f ? ? - ? ? ? = + = + = ? ? ? m ? ? ? 2 2 out out in max 2 2 out l rms o sw in max v v v 3.3 v 42 v - 3.3 v 1 1 i i 3.5 a 3.5 a 12 v l 12 42 v 5.6 h 600 khz ( ) ( ) f - = = = m out out in max ripple o sw in max v (v v ) 3.3 v x (42 v - 3.3 v) i 0.905 a v l 42 v x 5.6 h x 600 khz ( ) ( ) ( ) f - = = = m out in max out o min out ind sw in max v v v 42 v - 3.3 v 3.3 v l 4.8 h i k v 3.5 a x 0.3 42 v 600 khz
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 capacitance de-ratings for aging, temperature and dc bias increases this minimum value. for this example, 100 f ceramic capacitors with 5 m of esr is used. the derated capacitance is 70 f, well above the minimum required capacitance of 44.9 f. capacitors are generally rated for a maximum ripple current that can be filtered without degrading capacitor reliability. some capacitor data sheets specify the root mean square (rms) value of the maximum ripple current. equation 34 can be used to calculate the rms ripple current that the output capacitor must support. for this example, equation 34 yields 261 ma. (30) (31) (32) (33) (34) 9.2.2.4 catch diode the tps54340 requires an external catch diode between the sw terminal and gnd. the selected diode must have a reverse voltage rating equal to or greater than v in(max) . the peak current rating of the diode must be greater than the maximum inductor current. schottky diodes are typically a good choice for the catch diode due to their low forward voltage. the lower the forward voltage of the diode, the higher the efficiency of the regulator. typically, diodes with higher voltage and current ratings have higher forward voltages. a diode with a minimum of 42 v reverse voltage is preferred to allow input voltage transients up to the rated voltage of the tps54340. for the example design, the b560c-13-f schottky diode is selected for its lower forward voltage and good thermal characteristics compared to smaller devices. the typical forward voltage of the b560c-13-f is 0.70 volts at 5 a. the diode must also be selected with an appropriate power rating. the diode conducts the output current during the off-time of the internal power switch. the off-time of the internal switch is a function of the maximum input voltage, the output voltage, and the switching frequency. the output current during the off-time is multiplied by the forward voltage of the diode to calculate the instantaneous conduction losses of the diode. at higher switching frequencies, the ac losses of the diode need to be taken into account. the ac losses of the diode are due to the charging and discharging of the junction capacitance and reverse recovery charge. equation 35 is used to calculate the total power dissipation, including conduction losses and ac losses of the diode. the b560c-13-f diode has a junction capacitance of 300 pf. using equation 35 , the total loss in the diode is 2.42 watts. if the power supply spends a significant amount of time at light load currents or in sleep mode, consider using a diode which has a low leakage current and slightly higher forward voltage drop. (35) copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 27 product folder links: tps54340 ( ) ( ) ( ) ( ) ( ) f f f - + = + = + + = 2 out out in max j sw in d in max 2 v v i v d c v v d p v 2 42 v - 3.3 v 3.5 a x 0.7 v 300 pf x 600 khz x (42 v 0.7 v) 2.42 w 42 v 2 ( ) ( ) ( ) ( ) f - = = = m out out in max cout(rms) o sw in max v v v 3.3 v 42 v - 3.3 v i 261 ma 12 v l 12 42 v 5.6 h 600 khz < = = w oripple esr ripple v 16.5 mv r 18 m i 0.905 a f > = = m ? ? ? ? ? ? ? ? out sw oripple ripple 1 1 1 1 c x 11.4 f 16.5 mv 8 8 x 600 khz v 0.905 a i ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) > = m = m - 2 2 2 2 oh ol out o 2 2 2 2 f i i - i 2.625 a - 0.875 a c l x 5.6 h x 38.6 f 3.432 v 3.3 v v - v f d > = = m d out out sw out 2 i 2 1.75 a c 44.9 f v 600 khz x 0.13 v
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com 9.2.2.5 input capacitor the tps54340 requires a high quality ceramic type x5r or x7r input decoupling capacitor with at least 3 f of effective capacitance. some applications will benefit from additional bulk capacitance. the effective capacitance includes any loss of capacitance due to dc bias effects. the voltage rating of the input capacitor must be greater than the maximum input voltage. the capacitor must also have a ripple current rating greater than the maximum input current ripple of the tps54340. the input ripple current can be calculated using equation 36 . the value of a ceramic capacitor varies significantly with temperature and the dc bias applied to the capacitor. the capacitance variations due to temperature can be minimized by selecting a dielectric material that is more stable over temperature. x5r and x7r ceramic dielectrics are usually selected for switching regulator capacitors because they have a high capacitance to volume ratio and are fairly stable over temperature. the input capacitor must also be selected with consideration for the dc bias. the effective value of a capacitor decreases as the dc bias across a capacitor increases. for this example design, a ceramic capacitor with at least a 42 v voltage rating is required to support the maximum input voltage. common standard ceramic capacitor voltage ratings include 4 v, 6.3 v, 10 v, 16 v, 25 v, 50 v or 100 v. for this example, two 2.2 f, 100 v capacitors in parallel are used. table 2 shows several choices of high voltage capacitors. the input capacitance value determines the input ripple voltage of the regulator. the input voltage ripple can be calculated using equation 37 . using the design example values, i out = 3.5 a, c in = 4.4 f, ? sw = 600 khz, yields an input voltage ripple of 331 mv and a rms input ripple current of 1.74 a. (36) (37) table 2. capacitor types value ( f) eia size voltage dialectric comments 1 to 2.2 100 v 1210 grm32 series 1 to 4.7 50 v 1 100 v 1206 grm31 series 1 to 2.2 50 v 1 to 1.8 50 v 2220 1 to 1.2 100 v vj x7r series 1 to 3.9 50 v 2225 1 to 1.8 100 v x7r 1 to 2.2 100 v 1812 c series c4532 1.5 to 6.8 50 v 1 to 2.2 100 v 1210 c series c3225 1 to 3.3 50 v 1 to 4.7 50 v 1210 1 100 v x7r dielectric series 1 to 4.7 50 v 1812 1 to 2.2 100 v 9.2.2.6 bootstrap capacitor selection a 0.1- f ceramic capacitor must be connected between the boot and sw terminals for proper operation. a ceramic capacitor with x5r or better grade dielectric is recommended. the capacitor should have a 10 v or higher voltage rating. 28 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340 f d = = = m out in in sw i 0.25 3.5 a 0.25 v 331 mv c 4.4 f 600 khz ( ) ( ) ( ) ( ) ( ) ( ) - = = = out in min out out ci rms in min in min v v 6 v - 3.3 v v 3.3 v i i x x 3.5 a 1.74 a v v 6 v 6 v
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 9.2.2.7 undervoltage lockout set point the undervoltage lockout (uvlo) can be adjusted using an external voltage divider on the en terminal of the tps54340. the uvlo has two thresholds, one for power up when the input voltage is rising and one for power down or brown outs when the input voltage is falling. for the example design, the supply should turn on and start switching once the input voltage increases above 5.75 v (uvlo start). after the regulator starts switching, it should continue to do so until the input voltage falls below 4.5 v (uvlo stop). programmable uvlo threshold voltages are set using the resistor divider of r uvlo1 and r uvlo2 between vin and ground connected to the en terminal. equation 2 and equation 3 calculate the resistance values necessary. for the example application, a 365 k between vin and en (r uvlo1 ) and a 86.6 k between en and ground (r uvlo2 ) are required to produce the 8 v and 6.25 v start and stop voltages. (38) (39) 9.2.2.8 output voltage and feedback resistors selection the voltage divider of r5 and r6 sets the output voltage. for the example design, 10.2 k was selected for r6. using equation 1 , r5 is calculated as 31.9 k . the nearest standard 1% resistor is 31.6 k . due to the input current of the fb terminal, the current flowing through the feedback network should be greater than 1 a to maintain the output voltage accuracy. this requirement is satisfied if the value of r6 is less than 800 k . choosing higher resistor values decreases quiescent current and improves efficiency at low output currents but may also introduce noise immunity problems. (40) 9.2.2.9 compensation there are several methods to design compensation for dc-dc regulators. the method presented here is easy to calculate and ignores the effects of the slope compensation that is internal to the device. since the slope compensation is ignored, the actual crossover frequency will be lower than the crossover frequency used in the calculations. this method assumes the crossover frequency is between the modulator pole and the esr zero and the esr zero is at least 10 times greater the modulator pole. to get started, the modulator pole, ? p(mod) , and the esr zero, ? z1 must be calculated using equation 41 and equation 42 . for c out , use a derated value of 70 f. use equations equation 43 and equation 44 to estimate a starting point for the crossover frequency, ? co. for the example design, ? p(mod) is 2411 hz and ? z(mod) is 455 khz. equation 42 is the geometric mean of the modulator pole and the esr zero and equation 44 is the mean of modulator pole and the switching frequency. equation 43 yields 33.1 khz and equation 44 gives 26.9 khz. use the lower value of equation 43 or equation 44 for an initial crossover frequency. for this example, the target ? co is 26.9 khz. next, the compensation components are calculated. a resistor in series with a capacitor is used to create a compensating zero. a capacitor in parallel to these two components forms the compensating pole. (41) (42) (43) (44) copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 29 product folder links: tps54340 f f f = = = sw co p(mod) x 600 khz 2411 hz x 26.9 khz 2 2 f f f = = = co p(mod) x z(mod) 2411 hz x 455 khz 33.1 khz ( ) f = = = p p w m z mod esr out 1 1 455 khz 2 r c 2 5 m 70 f ( ) ( ) f = = = p p m out max p mod out out i 3.5 a 2411 hz 2 v c 2 3.3 v 70 f ? ? = = w = w ? ? out hs ls v - 0.8 v 3.3 v - 0.8 v r r x 10.2 k x 31.9 k 0.8 v 0.8 v = = = w + m + w ena uvlo2 start ena 1 uvlo1 v 1.2 v r 87.8 k v - v 5.75 v - 1.2 v 1.2 a i 365 k r = = = w m start stop uvlo1 hys v - v 5.75 v - 4.5 v r 368 k i 3.4 a
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com to determine the compensation resistor, r4, use equation 45 . assume the power stage transconductance, gmps, is 12 a/v. the output voltage, v o , reference voltage, v ref , and amplifier transconductance, gmea, are 5 v, 0.8 v and 350 a/v, respectively. r4 is calculated to be 11.6 k and a standard value of 11.5 k is selected. use equation 46 to set the compensation zero to the modulator pole frequency. equation 46 yields 5740 pf for compensating capacitor c5. 5600 pf is used for this design. (45) (46) a compensation pole can be implemented if desired by adding capacitor c8 in parallel with the series combination of r4 and c5. use the larger value calculated from equation 47 and equation 48 for c8 to set the compensation pole. the selected value of c8 is 47 pf for this design example. (47) (48) 9.2.2.10 discontinuous conduction mode and eco-mode boundary with an input voltage of 12 v, the power supply enters discontinuous conduction mode when the output current is less than 342 ma. the power supply enters eco-mode when the output current is lower than 31.4 ma. the input current draw is 237 a with no load. 9.2.2.11 power dissipation the following formulas show how to estimate the tps54340 power dissipation under continuous conduction mode (ccm) operation. these equations should not be used if the device is operating in discontinuous conduction mode (dcm). the power dissipation of the ic includes conduction loss (p cond ), switching loss (p sw ), gate drive loss (p gd ) and supply current (p q ). example calculations are shown with the 12 v typical input voltage of the design example. (49) spacer (50) spacer (51) spacer (52) where: i out is the output current (a). r ds(on) is the on-resistance of the high-side mosfet ( ). v out is the output voltage (v). v in is the input voltage (v). ? sw is the switching frequency (hz). trise is the sw terminal voltage rise time and can be estimated by trise = v in x 0.16ns/v + 3.0ns. q g is the total gate charge of the internal mosfet. 30 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340 = = m = q in q p v i 12 v 146 a 0.0018 w f = = = gd in g sw p v q 12 v 3nc 600 khz 0.022 w f = = = sw in sw out rise p v i t 12 v 600 khz 3.5 a 4.9 ns 0.123 w ( ) ( ) ? ? = = w = ? ? 2 2 out cond out ds on in v 3.3 v p i r 3.5 a 92 m 0.31 w v 12 v f = = = p w p 1 1 c8 46.1 pf r4 x sw x 11.5 k x 600 khz x m w = = = w out esr c x r 70 f x 5 m c8 30.4 pf r4 11.5 k f = = = p p w p(mod) 1 1 c5 5740 pf 2 r4 x 2 11.5 k x 2411 hz f ? ? p ? ? ? ? p m ? ? = = = w ? ? ? ? m ? ? ? ? f co out out ref 2 c v 2 26.9 khz 70 3.3 v r4 x x 11.6 k gmps v x gmea 12 a / v 0.8 v x 350 a / v
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 i q is the operating nonswitching supply current. therefore, (53) for given t a , (54) for given t jmax = 150 c (55) where: ptot is the total device power dissipation (w), t a is the ambient temperature ( c). t j is the junction temperature ( c). r th is the thermal resistance of the package ( c/w). t jmax is maximum junction temperature ( c) t amax is maximum ambient temperature ( c). there will be additional power losses in the regulator circuit due to the inductor ac and dc losses, the catch diode and pcb trace resistance impacting the overall efficiency of the regulator. 9.2.3 application curves figure 38. line transient (8 v to 40 v) figure 37. load transient figure 39. start-up with vin figure 40. start-up with en copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 31 product folder links: tps54340 time = 2 ms/div 2 v/div 5 v/div 2 v/div c3: en c2: v out c3c2 c1 c1: v in time = 2 ms/div 2 v/div 5 v/div 2 v/div c1: v in c3: en c2: v out c2 c3 c1 time = 100 s/div m 100 mv/div c3: v ac coupled out 1 a/div c4: i out c4c3 time = 4 ms/div 20 mv/div 10 v/div v v offset out -3.3 v in ( ) ( ) = - th tot a max j max t t r p = + j a th tot t t r p = + + + = + + + = tot cond sw gd q p p p p p 0.31 w 0.123 w 0.022 w 0.0018 w 0.457 w
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com i out = 3.5 a i out = 100 ma figure 41. output ripple ccm figure 42. output ripple dcm no load i out = 3.5 a figure 43. output ripple psm figure 44. input ripple ccm i out = 100 ma v in = 5.5 v no load v in = 12v v out = 5 v en floating figure 45. input ripple dcm figure 46. low dropout operation 32 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340 time = 2 s/div m 500 ma/div 10 v/div 50 mv/div c3: v ac coupled in c1: sw c4: i l c3 c4 c1 time = 20 s/div m 200 ma/div 2 v/div 20 mv/div c3: v ac coupled out c1: sw c4: i l c3 c4 time = 2 s/div m 1 a/div 10 v/div 200 mv/div c3: v ac coupled in c1: sw c4: i l c2c4 c1 time = 2 ms/div 200 ma/div 10 v/div 20 mv/div c1: sw c4: i l c2: v ac coupled out c2 c4 c1 time = 2 s/div m 1 a/div 10 v/div 20 mv/div c2: v ac coupled out c1: sw c4: i l c2c4 c1 time = 2 s/div m 500 ma/div 10 v/div 10 mv/div c2: v ac coupled out c1: sw c4: i l c2 c4 c1
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 i out = 100 ma en floating i out = 1 a en floating figure 47. low dropout operation figure 48. low dropout operation v out = 3.3 v ? sw = 600 khz v out = 3.3 v ? sw = 600 khz figure 49. efficiency vs load current figure 50. light load efficiency v out = 5 v ? sw = 600 khz v out = 5 v ? sw = 600 khz figure 51. efficiency vs load current figure 52. light load efficiency copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 33 product folder links: tps54340 0 10 20 30 40 50 60 70 80 100 0 0.5 1.0 1.5 2.0 i - output current - a o efficiency - % 2.5 3.0 90 3.5 4.0 6vin 12vin24vin 36vin42vin 0 10 20 30 40 50 60 70 80 100 0.001 0.01 i - output current - a o efficiency - % 0.1 90 1 6vin 12vin24vin 36vin42vin 0 10 20 30 40 50 60 70 80 100 0 0.5 1.0 1.5 2.0 i - output current - a o efficiency - % 2.5 3.0 90 3.5 6vin 12vin24vin 36vin42vin 0 10 20 30 40 50 60 70 80 100 0.001 0.01 i - output current - a o efficiency - % 0.1 90 1 6vin 12vin24vin 36vin42vin time = 40 s/div m 2 v/div v in v out time = 40 s/div m 2 v/div v in v out
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com v in = 12 v v out = 3.3 v i out = 3.5 a v in = 12 v v out = 3.3 v ? sw = 600 khz figure 53. overall loop frequency response figure 54. regulation vs load current v out = 3.3 v i out = 3.5 a ? sw = 600 khz figure 55. regulation vs input voltage 10 power supply recommendations the device are designed to operate from an input voltage supply range between 4.5 v and 42 v. this input supply should be well regulated. if the input supply is located more than a few inches from the tps54340 converter additional bulk capacitance may be required in addition to the ceramic bypass capacitors. an electrolytic capacitor with a value of 100 f is a typical choice. 34 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340 -0.3 0.2 -0.1 0 0.1 0.2 0.3 5 10 15 20 v - input voltage - v in output voltage deviation - % 25 30 35 40 45 -60 -40 -20 0 20 60 10 100 frequency - hz gain - db 40 -180 -120 -60 0 60 120 180 10000 100000 1000000 phase - degree 1000 phase gain -1 -0.8 -0.6 0.4 -0.2 0 0.2 0.4 0.6 1 0 0.5 1.0 1.5 2.0 i - output current - a o output voltage deviation - % 2.5 3.0 0.8 3.5
tps54340 www.ti.com slvsbk0b ? october 2012 ? revised march 2014 11 layout 11.1 layout guidelines layout is a critical portion of good power supply design. there are several signal paths that conduct fast changing currents or voltages that can interact with stray inductance or parasitic capacitance to generate noise or degrade performance ? to reduce parasitic effects, the vin terminal should be bypassed to ground with a low esr ceramic bypass capacitor with x5r or x7r dielectric. ? care should be taken to minimize the loop area formed by the bypass capacitor connections, the vin terminal, and the anode of the catch diode. ? the gnd terminal should be tied directly to the power pad under the ic and the powerpad ? . ? the powerpad ? should be connected to internal pcb ground planes using multiple vias directly under the ic. ? the sw terminal should be routed to the cathode of the catch diode and to the output inductor. ? since the sw connection is the switching node, the catch diode and output inductor should be located close to the sw terminals, and the area of the pcb conductor minimized to prevent excessive capacitive coupling. ? for operation at full rated load, the top side ground area must provide adequate heat dissipating area. ? the rt/clk terminal is sensitive to noise so the rt resistor should be located as close as possible to the ic and routed with minimal lengths of trace. ? the additional external components can be placed approximately as shown. ? it may be possible to obtain acceptable performance with alternate pcb layouts, however this layout has been shown to produce good results and is meant as a guideline. 11.2 layout example figure 56. pcb layout example 11.2.1 estimated circuit area boxing in the components in the design of figure 36 the estimated printed circuit board area is 1.025 in 2 (661 mm 2 ). this area does not include test points or connectors. copyright ? 2012 ? 2014, texas instruments incorporated submit documentation feedback 35 product folder links: tps54340 bootvin en rt/clk sw gnd comp fb inputbypass capacitor uvloadjust resistors frequencyset resistor compensationnetwork resistordivider outputinductor output capacitor vout vin topside ground area catchdiode route boot capacitor trace on another layer to provide wide path for topside ground thermal via signal via
tps54340 slvsbk0b ? october 2012 ? revised march 2014 www.ti.com 12 device and documentation support 12.1 trademarks eco-mode, powerpad, webench are trademarks of texas instruments. 12.2 electrostatic discharge caution these devices have limited built-in esd protection. the leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the mos gates. 12.3 glossary slyz022 ? ti glossary . this glossary lists and explains terms, acronyms, and definitions. 13 mechanical, packaging, and orderable information the following pages include mechanical packaging and orderable information. this information is the most current data available for the designated devices. this data is subject to change without notice and revision of this document. for browser-based versions of this data sheet, refer to the left-hand navigation. 36 submit documentation feedback copyright ? 2012 ? 2014, texas instruments incorporated product folder links: tps54340
package option addendum www.ti.com 31-oct-2013 addendum-page 1 packaging information orderable device status (1) package type package drawing pins package qty eco plan (2) lead/ball finish (6) msl peak temp (3) op temp (c) device marking (4/5) samples tps54340dda active so powerpad dda 8 75 green (rohs & no sb/br) cu nipdauag level-2-260c-1 year -40 to 125 54340 tps54340ddar active so powerpad dda 8 2500 green (rohs & no sb/br) cu nipdauag level-2-260c-1 year -40 to 125 54340 (1) the marketing status values are defined as follows: active: product device recommended for new designs. lifebuy: ti has announced that the device will be discontinued, and a lifetime-buy period is in effect. nrnd: not recommended for new designs. device is in production to support existing customers, but ti does not recommend using this part in a new design. preview: device has been announced but is not in production. samples may or may not be available. obsolete: ti has discontinued the production of the device. (2) eco plan - the planned eco-friendly classification: pb-free (rohs), pb-free (rohs exempt), or green (rohs & no sb/br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. tbd: the pb-free/green conversion plan has not been defined. pb-free (rohs): ti's terms "lead-free" or "pb-free" mean semiconductor products that are compatible with the current rohs requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. where designed to be soldered at high temperatures, ti pb-free products are suitable for use in specified lead-free processes. pb-free (rohs exempt): this component has a rohs exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. the component is otherwise considered pb-free (rohs compatible) as defined above. green (rohs & no sb/br): ti defines "green" to mean pb-free (rohs compatible), and free of bromine (br) and antimony (sb) based flame retardants (br or sb do not exceed 0.1% by weight in homogeneous material) (3) msl, peak temp. - the moisture sensitivity level rating according to the jedec industry standard classifications, and peak solder temperature. (4) there may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device. (5) multiple device markings will be inside parentheses. only one device marking contained in parentheses and separated by a "~" will appear on a device. if a line is indented then it is a continuation of the previous line and the two combined represent the entire device marking for that device. (6) lead/ball finish - orderable devices may have multiple material finish options. finish options are separated by a vertical ruled line. lead/ball finish values may wrap to two lines if the finish value exceeds the maximum column width. important information and disclaimer: the information provided on this page represents ti's knowledge and belief as of the date that it is provided. ti bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. efforts are underway to better integrate information from third parties. ti has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. ti and ti suppliers consider certain information to be proprietary, and thus cas numbers and other limited information may not be available for release.
package option addendum www.ti.com 31-oct-2013 addendum-page 2 in no event shall ti's liability arising out of such information exceed the total purchase price of the ti part(s) at issue in this document sold by ti to customer on an annual basis. other qualified versions of tps54340 : ? automotive: tps54340-q1 note: qualified version definitions: ? automotive - q100 devices qualified for high-reliability automotive applications targeting zero defects
tape and reel information *all dimensions are nominal device package type package drawing pins spq reel diameter (mm) reel width w1 (mm) a0 (mm) b0 (mm) k0 (mm) p1 (mm) w (mm) pin1 quadrant tps54340ddar so power pad dda 8 2500 330.0 12.8 6.4 5.2 2.1 8.0 12.0 q1 package materials information www.ti.com 13-may-2013 pack materials-page 1
*all dimensions are nominal device package type package drawing pins spq length (mm) width (mm) height (mm) tps54340ddar so powerpad dda 8 2500 366.0 364.0 50.0 package materials information www.ti.com 13-may-2013 pack materials-page 2



important notice texas instruments incorporated and its subsidiaries (ti) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per jesd46, latest issue, and to discontinue any product or service per jesd48, latest issue. buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. all semiconductor products (also referred to herein as ? components ? ) are sold subject to ti ? s terms and conditions of sale supplied at the time of order acknowledgment. ti warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in ti ? s terms and conditions of sale of semiconductor products. testing and other quality control techniques are used to the extent ti deems necessary to support this warranty. except where mandated by applicable law, testing of all parameters of each component is not necessarily performed. ti assumes no liability for applications assistance or the design of buyers ? products. buyers are responsible for their products and applications using ti components. to minimize the risks associated with buyers ? products and applications, buyers should provide adequate design and operating safeguards. ti does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which ti components or services are used. information published by ti regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from ti under the patents or other intellectual property of ti. reproduction of significant portions of ti information in ti data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. ti is not responsible or liable for such altered documentation. information of third parties may be subject to additional restrictions. resale of ti components or services with statements different from or beyond the parameters stated by ti for that component or service voids all express and any implied warranties for the associated ti component or service and is an unfair and deceptive business practice. ti is not responsible or liable for any such statements. buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements concerning its products, and any use of ti components in its applications, notwithstanding any applications-related information or support that may be provided by ti. buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. buyer will fully indemnify ti and its representatives against any damages arising out of the use of any ti components in safety-critical applications. in some cases, ti components may be promoted specifically to facilitate safety-related applications. with such components, ti ? s goal is to help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and requirements. nonetheless, such components are subject to these terms. no ti components are authorized for use in fda class iii (or similar life-critical medical equipment) unless authorized officers of the parties have executed a special agreement specifically governing such use. only those ti components which ti has specifically designated as military grade or ? enhanced plastic ? are designed and intended for use in military/aerospace applications or environments. buyer acknowledges and agrees that any military or aerospace use of ti components which have not been so designated is solely at the buyer ' s risk, and that buyer is solely responsible for compliance with all legal and regulatory requirements in connection with such use. ti has specifically designated certain components as meeting iso/ts16949 requirements, mainly for automotive use. in any case of use of non-designated products, ti will not be responsible for any failure to meet iso/ts16949. products applications audio www.ti.com/audio automotive and transportation www.ti.com/automotive amplifiers amplifier.ti.com communications and telecom www.ti.com/communications data converters dataconverter.ti.com computers and peripherals www.ti.com/computers dlp ? products www.dlp.com consumer electronics www.ti.com/consumer-apps dsp dsp.ti.com energy and lighting www.ti.com/energy clocks and timers www.ti.com/clocks industrial www.ti.com/industrial interface interface.ti.com medical www.ti.com/medical logic logic.ti.com security www.ti.com/security power mgmt power.ti.com space, avionics and defense www.ti.com/space-avionics-defense microcontrollers microcontroller.ti.com video and imaging www.ti.com/video rfid www.ti-rfid.com omap applications processors www.ti.com/omap ti e2e community e2e.ti.com wireless connectivity www.ti.com/wirelessconnectivity mailing address: texas instruments, post office box 655303, dallas, texas 75265 copyright ? 2014, texas instruments incorporated


▲Up To Search▲   

 